Oracle® Database SQL Reference 10g Release 2 (10.2) Part Number B14200-02 |
|
|
PDF · Mobi · ePub |
Use the ALTER
FUNCTION
statement to recompile an invalid standalone stored function. Explicit recompilation eliminates the need for implicit run-time recompilation and prevents associated run-time compilation errors and performance overhead.
The ALTER
FUNCTION
statement is similar to ALTER PROCEDURE. For information on how Oracle Database recompiles functions and procedures, see Oracle Database Concepts.
This statement does not change the declaration or definition of an existing function. To redeclare or redefine a function, use the CREATE
FUNCTION
statement with the OR
REPLACE
clause. See CREATE FUNCTION.
The function must be in your own schema or you must have ALTER
ANY
PROCEDURE
system privilege.
Specify the schema containing the function. If you omit schema
, Oracle Database assumes the function is in your own schema.
Specify the name of the function to be recompiled.
Specify COMPILE
to cause Oracle Database to recompile the function. The COMPILE
keyword is required. If Oracle Database does not compile the function successfully, you can see the associated compiler error messages with the SQL*Plus command SHOW
ERRORS
.
During recompilation, Oracle Database drops all persistent compiler switch settings, retrieves them again from the session, and stores them at the end of compilation. To avoid this process, specify the REUSE
SETTINGS
clause.
Specify DEBUG
to instruct the PL/SQL compiler to generate and store the code for use by the PL/SQL debugger. Specifying this clause has the same effect as specifying PLSQL_DEBUG
= TRUE
in the compiler_parameters_clause
.
Use this clause to specify a value for one of the PL/SQL persistent compiler parameters. The value of these initialization parameters at the time of compilation is stored with the unit's metadata. You can learn the value of such a parameter by querying the appropriate *_PLSQL_OBJECT_SETTINGS
view. The PL/SQL persistent parameters are PLSQL_OPTIMIZE_LEVEL
, PLSQL_CODE_TYPE
, PLSQL_DEBUG
, PLSQL_WARNINGS
, PLSQL_CCFLAGS
, and NLS_LENGTH_SEMANTICS
.
You can specify each parameter only once in each statement. Each setting is valid only for the current library unit being compiled and does not affect other compilations in this session or system. To affect the entire session or system, you must set a value for the parameter using the ALTER
SESSION
or ALTER
SYSTEM
statement.
If you omit any parameter from this clause and you specify REUSE SETTINGS
, then if a value was specified for the parameter in an earlier compilation of this library unit, Oracle Database uses that earlier value. If you omit any parameter and either you do not specify REUSE SETTINGS
or no value has been specified for the parameter in an earlier compilation, then the database obtains the value for that parameter from the session environment.
Restriction on the compiler_parameters_clause You cannot set a value for the PLSQL_DEBUG
parameter if you also specify DEBUG
, because both clauses set the PLSQL_DEBUG
parameter, and you can specify a value for each parameter only once.
See Also:
Oracle Database Reference for the valid values and semantics of each of these parameters and PL/SQL User's Guide and Reference for information on using thePLSQL_CCFLAGS
parameter for PL/SQL conditional compilationSpecify REUSE
SETTINGS
to prevent Oracle from dropping and reacquiring compiler switch settings. With this clause, Oracle preserves the existing settings and uses them for the recompilation of any parameters for which values are not specified elsewhere in this statement.
For backward compatibility, Oracle Database sets the persistently stored value of the PLSQL_COMPILER_FLAGS
initialization parameter to reflect the values of the PLSQL_CODE_TYPE
and PLSQL_DEBUG
parameters that result from this statement.
See Also:
Oracle Database Reference for the valid values and semantics of each of these parameters and PL/SQL User's Guide and Reference and Oracle Database Application Developer's Guide - Fundamentals for more information on the interaction of thePLSQL_COMPILER_FLAGS
initialization parameter with the COMPILE
clauseRecompiling a Function: Example To explicitly recompile the function get_bal
owned by the sample user oe
, issue the following statement:
ALTER FUNCTION oe.get_bal COMPILE;
If Oracle Database encounters no compilation errors while recompiling get_bal
, then get_bal
becomes valid. Oracle Database can subsequently execute it without recompiling it at run time. If recompiling get_bal
results in compilation errors, then Oracle Database returns an error, and get_bal
remains invalid.
Oracle Database also invalidates all objects that depend upon get_bal
. If you subsequently reference one of these objects without explicitly recompiling it first, then Oracle Database recompiles it implicitly at run time.